Corley: Courimore coming at you to let you know about the vigilantes. Of course, everybody, I mean if you if you watch the scrap, if you listen to the scrap at all, you know about the vigilantes. But I want to be very clear and let everybody know we are moving to Patreon. The vigilantes are moving to Patreon. There's been so many people who said, hey, I don't do Facebook. I can't be a part of the Vigilantes. I'm not on Facebook. And I get it We get it. So now we are moving to Patreon. It is independent of any of the social media platforms. It is its own thing. You can join us on Patreon. So what does that mean if you're already a vigilante? Man, go join Patreon. We will stop your payment. We will refund if you are on an annual subscription, we will refund what has remained. We will make it happen. We are going to take care of you and get you in there. It's already a beautiful platform. So much going on in there. These are the things. If you're not a vigilante I'm just asking you why not go to the Patreon. It is patreon. com slash the vigilantes. And you get access to the vigilante only swag shop. The fire away live Q<unk>A's behind the scenes of the scrap. You influence the scrap on where it's going to go. Member only exclusive live videos. complete access to all the past archives, all the past forums, all the past QA's, the 15% off vigilante code for the firehousevigilance. com store. access to the After party, man. I mean that's every scrap. The after party. It's unbelievable. And of course, the VIP forums where we talk to some of the best in the business one-on-one in a giant meeting where everybody has a voice. It's exciting. So if you're not a vigilante, go be one. If you are a vigilante, go sign up at patreon. com so that you can get it transferred over. It is gonna be It's going to be a fun transfer, but we're making it happen. It's already been amazing today. Over I think over a hundred people today have already signed up and we just announced it this morning. So go be a part Vigilantes, patreon. com slash the vigilantes. Or go to firehousevigilance. com and you can click the button there.
Corley: Very, very easy. Be a part. Be one of the cool kids. Why not? Make it happen. Love you all See ya. Corley Moore, Firehouse Vigilance. It is weekly scrap number 248. Tonight's guest is Dennis Lagueer. He retired as a captain out of Oakland, California, creator of the Turbo Back Pressure Device The 1 and 3 16th smooth board tip matching nozzle pressure GPM fogs to smooth board project and true hose spec movement, a panel member on ULFRSI's fire streams and coordinated attack studies Author of the Water Supply and Hose Appliance Chapter in the Fire Engineering Handbook. Contributor in Fire Engineering magazine Man, he has degrees. He's got multiple degrees in vocational education. He is owner of La Gear Engineering, Fire Department Consulting. He is an advisor to Hen Nozzle Company. And has provided technical advice to some of the largest fire agencies in North America, including Portland, Seattle, Boston, Calgary, and the city of New York. More importantly than all of that, he is one of the smartest people in the fire service, and that's my opinion. He's the he's the type of person that can use porous in a sentence and make me understand what he's talking about, right? It is my pleasure to have him on as the guest for scrap number 248, Dennis Laguerre. Welcome, my brother
Dennis Lagueer: Thanks for the intro. Happy Memorial Day. There is a good conference series that is put out on the West Coast by the San Francisco Fire. Fire department. I think it's on the back of my short short here. What's it say? Like battleground. Corley: Battleground, fire ground. Dennis Lagueer: Battleground and fire ground. And they they always choose one. member of the fire service, usually executive member, and then a fairly high member of the military, including up to like I think they had the chief highest enlisted member of the army ma master chief grippy I think was his name so that's where I got this shirt tipped my hat to the Master Chief there and all of our armed services and those who served Corley: I love it. I absolutely love it. Thank you for the Memorial Day shout-out. Is there anything I missed? Anything you want to add to the intro? Dennis Lagueer: No. No, it's more more than generous. Just trying to stay involved. I think a lot of people know I've tried to stay involved at a pretty deep level over the last you know decade or so, mainly around water movement and fire stream development which really were my passions in the fire service. From actually wildly anti-structural, I've kind of had a rebirth of my wildland chops over the last couple years providing advice to hen nozzles. That's kind of where I started with their nozzle.
Corley: Love it Dennis Lagueer: Yeah. Corley: Man, people are already chiming in. You've already got your first question coming at you, so that's already great when it's already starting out that way. Audience, please, please, please post your questions in the chat if you want Dennis to get them and answer them The more you articulate them, the better I can I can I can serve them up to him and he can crush them. So please, please, please throw them up there. Greg White said, LFG, four rocker horns and about 18 exclamation points. Tailboard Misfits said, let's get nerdy. Two rocker horns. Can't wait. Cody Brooks said settled in and ready for this one. Time to go to school. Checking in from Florida. Eddie J said time to nerd out folks. Let's go. That's with six O's. Maybe eight. There's so much Map Music said LFG, get ready to be nerds. I see a theme. I see a theme here. And Josh Everett said, got my journal ready to take notes. Dan Bender absolutely captured it with his first sentence. He said, this may be a scrap. That needs watched numerous times. My brain doesn't usually keep up with the Dennis Laguerre info overload. And I'll tell you this: if you haven't watched his earlier scraps, every one of them needs to be watched multiple times just to take the notes and restudy the notes. So absolutely. Alright, all that being said, let's do the let's do the important let's get the sponsors so we can get to scrapping I cannot, I was about to say let's get to the questions, but I have to do the sponsors. let's talk about those beautiful sponsors. Keyhose, the OG sponsor of the scrap. Check them out online at keyhose. com and follow them on Facebook. Affordable Drill Towers on a mission to bring you cost-effective and versatile training props like the Affordable Belout Prop, which allows you to practice window bailouts, ladder bailouts, and ladder high point rescues They also make the affordable standpipe prop, which you can roll into the classroom or you can do standpipe theory, but then you roll it into the parking lot, you can actually pump realistic flows and pressures. And of course, their mainstay, the affordable drill tower, it comes in several configurations and standard with a standpipe system. Choose from one or two sets of stairs.
Corley: Integrate it into your existing Conex boxes for multi-story access or freestanding on a slab. All models are NFPA 1402 compliant and gain you ISO credit. The only thing that you can't do on an affordable drill tower is live fire training. Call Steve 844-55 Tower or drop an email to info at affordable drilltowers. com. Firestationfurniture. com provides a complete line of quality furniture for your firehouse. It is firefighter-owned and operated. They understand the strain that firefighters put on furniture and offer furniture that's built to last. Visit www. fire stationfurniture. com for more information. And I love their byline. It's an unofficial byline, I think, but it says quit blaming the recliner, right? And it's a great byline. So absolutely love it check them out. And with all that being said, we're ready to get to scrap. And Dennis, are you ready for the questions? Dennis Lagueer: Yeah. Just as a preference. Kind of basing this trap on my FDIC class this year, which was new, which was basically a Firestream Development Application class. With kind of my mindset this evening's just basically volume placement and velocity and key attributes to applying water from the small space to the medium to the large to the ultra-large space, some of the stuff that we should be talking about on a more detailed level in the fire service. So beautiful.
Corley: No, and and the FDIC class, bro, man. I love the graphic. The I mean there's so much to touch on. and that fact that's the one thing I kind of I try not to do too much graphical stuff when I'm talking about when I do the scrap because so many people listen to it. So I try not to throw up slides that people have to look at But I do want to talk and start right out the gate and talk about Firestream design, development, and application. I'll let you just kick it off and take it whatever direction you want with your intro, and then we'll go from there. You've already got questions stacking up that may or may not have to do with that topic, but go ahead. Dennis Lagueer: Yeah. you know, I I think it's important to kind of talk about like an attack package disclaimer here, you know, key sponsoring it. Cart's done a lot for the fire service with training and everything that's gone on, but ultimately the number one person or people that are most important is the firefighters that are using the equipment themselves, right? So based on their knowledge and understanding, how to get the maximum amount of coverage, cooling, and contraction. on your interior attacks, how to get your maximum amount of exterior water where it needs to go, different techniques you can use used to try to get, you know, some people say efficiency is like a dirty word. It's really effectiveness, right? Per gallon delivered, per person on the fire ground. that is manipulating items that move water. How can we get the fire extinguished as quickly as possible? and allow gross ventilation, right? Because people get what? Smoked before they're cooked. So the More aggressive we can be with applying water with a better knowledge base, the quicker we can basically recklessly ventilate. And we want to get to that reckless ventilation as quickly as possible. possible and the only way you can recklessly ventilate is if there's no fire.
Corley: Hold on a second. I gotta write down 811 because that is a beautiful beautiful quote when you talk about reckless ventilation. That is such a great way to state it. Dennis Lagueer: You should almost be able to say that on the radio if you're the nozzle man And you're done with your seat, you should go reckless vent, reckless vent. Corley: Yeah, just be like, well, we're we got water on the fire. You can open this thing up. Dennis Lagueer: Yeah, so and it's funny, like, you know, like just back to that knowledge and understanding component, like I was taught several things in Oakland that I don't think are taught a lot of other places. Condensed city. I was always supposed to go to the window. I was always supposed to look across. Often The building next to the building you're making your interior attack on would have siding on fire, so you can do a lot of extinguishment from the seat room especially our tighter residential neighborhoods or multiple family it's a wooden city then I was always taught to look up and the reason I'm looking up is I don't know whether I'm on a gable side or an eaveside and if I'm on an east side The next thing I was supposed to do is apply water up into the Eave. One thing that we did not do, at least the people that mentored me, there wasn't a heavy emphasis on hydraulic ventilation. And Hydraulic ventilation is extremely important. It's been tested, battleground tested, let's say in places like Detroit. And DC's very well known for it. and and it it's also now been validated and backed up by data and the residential studies and the multiple family dwelling studies from the U. S.
Corley: All the UL, yeah, all the UL FSRI stuff. Absolutely, brother. No, absolutely. Dennis Lagueer: I I would have been a hydraulic ventilating fool now if I was a firefighter. I just didn't know. Corley: Right. And that's and that's what it comes down to is learning those things that we don't figuring out what we don't know. And and that's the beauty of it. one of my favorite quotes, and I I referenced it kind of in your intro, and I use it in my class that I teach at FDIC Because I use I use Dennis Leghier in my class. But he says, once you have water on the fire, you should make the building as porous as possible. And I do love that quote. And that's where I always I make I make the mention of the porous, using the word porous. Dennis Lagueer: Sometimes I get these things back and I forget that I've said them. Brian Brush put me on a spot about traction and GPM, like a class he was giving. I don't know where you're going with this. And he's like, well, all GPN in the world doesn't mean anything if you can't hook it up, right? Like reaction force. And I just, I'm sure I said it, I just probably forgot.
Corley: Well you just said something beautiful. You just said something beautiful just earlier. You said per gallon delivered per person on the department. Man, that is a that is a like an amazing formula to run like to run your department by. No matter your staffing. Dennis Lagueer: Yeah. Yeah. You know you know you want to try to get you want you know you want to try to get that water where it belongs and you want to be You want to achieve a mastery level skill set not only comes through not only being nerdy and reading stuff and but it's also reflecting on fires that you've been to. Where you could have done a better job. And by the way, that doesn't mean all water is being applied to stuff that's on fire. You know, like you know, for for example, coming up into a slowly spreading fire in a cubicle office complex like coming out of steerwell and it's gotta be very hard for you to get water initially onto the cubicles that are burning And as sprinklers fail, efficiency goes down, it would behoove you to have the nozzle open and apply water between the plenum, the drop ceiling and the walls, and kind of cover the floor a little bit. We have a gigantic building, huge exposure. It might be occupied, it might not be occupied, but wetting 20 or 30 extra cubicles in the fire's path is like removing fuel from from its path. So you know five there is very val there's value in getting water on surfaces that are maybe preheated or in the path especially in those larger volume spaces.
Corley: You know just negating those BTUs before And it's hard to burn stuff that's wet. Dennis Lagueer: You know, that's just been my experience, you know. Corley: Hey and on on topic kind of what we were talking about, you just corrected a quote because I there's a quote I I that gets posted quite often that it's a slide in one of my presentations Man, I'm pulling a blank on it. And you just corrected it earlier. it wasn't even a month ago that you said actually here's the rest of the quote. Do you know what I'm talking about at all? Dennis Lagueer: Oh, I no yeah, almost nobody it's Corley: My variables, variables. Yeah, variables. Yeah, we should be inserting constants where variables exist. Dennis Lagueer: Yeah. Yeah, we should be inserting constants where variable variables exist and then my I always say you know if you're gonna insert a variable back it better have a large return on investment right I mean you can cut down to the bone like you know like you can you can get to a point where you're cutting bone and there there's muscle that should should be there. I'm not anti-option. You know, I'm just anti lots of options. My kind of like one of the things I think people don't understand sometimes when I'm talking about bulk bulk beds. Like I don't mind a rig that has bulk beds both inch and three quarter and two and a half having some pre-connected inch and three quarter and two and a half. I'm not sure it's necessary, you know, depending on staffing and rig concentration and everything. But I will tell you what is necessary If you have a pre-connected inch and three-quarter or a pre-connected two and a half, you shall have a pre- a bulk bed of inch and three quarters. three quarter and a bulk bed of large line right you know like you can pull up with a rig with no pre-connects and do just fine on all fires short medium, lengthy, complex, uncomplex stretches, right? A bulk bed will do all of those things from a th and by the way, I would argue that a bulk bed Does a three-length stretch a lot better than a 200-foot pre-connect does.
Corley: No, it's hard to argue. It's hard to argue if you actually get out and practice and put in the reps and actually test it. Dennis Lagueer: Well f a f a 200 foot pre-connect's always four lengths. Like there's there were plenty I made the mistake with a couple other people in Oakland making both cross lays 200 feet for a few months And I'm lucky I still have all my teeth. Because you know, I worked in a I worked in an area where I thought it would be okay, and then the bungalow battalion guys were crucifying me. They they wish they had two 150 pre-connects and then we gave them a bulk bed and I said now you have it we gave you your 150 pre-connect back and if the first line's 150 and the house only needs 50 feet in it it's only 100 feet from the rig you can always pull the second line from the bulk bed so bulk beds are really a multiversal tool and a pre-connect is not right so you can have a rig Without pre-connects, but you can't have a rig without bulk beds. At that point, to me, it's just not an engine.
Corley: All right. I know I love it. I love the I love the thing. Okay, are you ready for your first questions coming from the audience? Sure. Alright, this one was actually before the scrap ever started. So it's not even on topic, but I want to throw it at you and and and you can be a succinct or as in-depth as you want, but he said it comes from Kevin Kevin and he said, Dennis, can you explain how the pump rating on an apparatus is certified? Dennis Lagueer: I'll pump You know, it it it starts at the OEM manufacturer for like at Waterus when they get a oh when a OEM engine comes through, pierce. Rev group, whoever, you know, it's all in the pump and design curve. It gets the water, surhale. They do all the torque and numbers. They test it. in in factory with the known GP known horsepower and curve and final drive and then ship it And then the factory one, don't quote me on how long the UL pump test is, but part when you're buying a rig. You're paying for a UL certification. It's the longer duration certification at the manufacturer. Now that being said, one of the things that this actually brings into Focused here is manufacturers do stuff from draft. And one of the things on an attack package to work properly is that you have to pump it properly. And that means your panel should read very accurately. And Kyle Tone that works in Austin, that's on their apparatus committee, and me with these guys out of the Pacific Northwest, the rigs I've been spec inspecting out here, Rick Mosier from Olatha, Kansas, and Taylor Good Goodman from Pulhontan. we've been noticing for years that pump panels when they're gated don't read. the way they should. And Yakima Washington just bought new nozzles and hose and they had Brian Scott out, and he when he was gating, he was surprised. Because the discharge gauge they put on the outlet would read higher than the gated position. So it would be like you gate to 90 and the actual discharge would be 100 Or you gate to 95. So one of the things you have to realize is when water travels quickly through a tube, sidewall pressure goes down. So that's why they say when your LDH is getting soft or your five inch is getting soft.
Dennis Lagueer: you're running out of water because it's a little convoluted, but water traveling fast through a pipe actually exerts less pressure out So when you gate, when you gate your discharge, right now this is the valve body, and I'm for people who are listening, I'm making a fist, my other fingers touching my fist, that's where the pressure pickup is. When you gate, you create a reduction in surface area so the water velocity speeds up. So your panel will read lighter than your actual discharge pressure. So the more you gate, the bigger the problem is. Like you could you can like if a city like Tucson, surrounded by hills, a lot of hydrants are 100 PSI the rigs idle at 50, you're at 150 pounds, you pull some two and a half, you want a 70 pound discharge, you can gate till it says 70 on the panel, but your actual discharge pressure might be 10 Corley: Yeah, nine. Dennis Lagueer: So all the people that have said that they're two and a half are over pumped, even when the panel reads right, you know, a lot often they're correct. So we we have fixed that. You know, I I I've had other things I've been dealing with but there will be an article out most of the OEM manufacturers understand this now and it'll be a process over the next few years
Corley: to get all that stuff straightened out without hurting in the what is what it what was what was the general fix for oh it's pretty easy you just go back true ID hose from key I was getting ready to ask is it just like saying true discharge Dennis Lagueer: Yeah, you just go you just go back to the future. So the reason people like True ID hosts, it's modern technology. There's a lot of stuff to it. But basically I remembered thicker, stiffer, bulkier hose and the rigs they used instead of using the valve body port Which which didn't exist. The valves didn't have multiple ports on them. they used to drill a hole in the pipe near the actual discharge and that's where the pressure hydraulic pickup would go. So We've just returned to the proper place to put the drip the pressure pickup. Corley: Where there are. Dennis Lagueer: So now you're way away from the turbulent flow, but you also get another benefit. If there's a lot of bends in the piping and stuff. You you don't have that error either. So you don't you you get all the recorded plumbing loss and you also get a panel gauge that will read
Corley: a hundred percent accurate right so i'm gonna try and simplify it for firefighters and myself it's basically put the at where they actually do the pickup as close to the actual discharge as possible Dennis Lagueer: Right. So essentially it's within the pump house still. Like, you know, you could get super crazy and do transducer pickups and put them right at all the discharges, but as long as you're like The rear discharges, as long as you're in a straight run of pipe, right where it leaves, it hand line flows that two and a half going back. I always spec three inch just doesn't have enough friction loss in it. Corley: Okay Dennis Lagueer: for it to be a subs significant things. You gotta do a few tricks on your side discharges. You gotta push them back in so you get a nice pipe nipple So you can actually be, you know, quite a ways away from turbulent water, which isn't which isn't really a problem. you can do it as long as you're not trying to you brings to brings to another thing like everybody's obsessed with 48 inch pump houses or 45 inch pump houses and If you do a turning radius study, the difference between like a 48 and 50-inch pump house really means nothing. But if you're trying to stop everything in there and you like wonder why your gauges don't read accurate and It takes forever to get your rig back from the mechanic shop because they got to go through one valve to get to another valve. You know, I'm constantly talking people up in panel size. Like You're not San Francisco. You don't need a 45-inch panel. You know, you could do a 50-inch panel and make your mechanics day, and you'll have no leaky valves, and your panel will have a nice layout, and everybody will understand it And you've only you've only knocked a few inches off your turning radius and you're a suburban fire department. You don't need a 45-inch pump. panel and a 27 foot long rig, you know.
Corley: I love it. No, I love it. But basically get past the bins. Is that yours? Dennis Lagueer: Was that me? It was me. Corley: Okay, okay, just making sure. get past the bins. Get to a straight run, as straight a run as you can get before you do your pickup. Dennis Lagueer: Yep. I that's basically. Corley: I'm trying to melt it down. I'm trying to melt it down. Dennis Lagueer: So the reason you don't have problems at factories when you do one leg at a time, one run at a time, is that All of the OEM manufacturers basically test from draft. They have a drafting pit or a lake you go to. So what's that mean? No pump, no hydrant pressure. So that means if you test one line at a time. it'll be fully open. So you'll never get a panel that reads one pressure and then the discharge pressure is greater. That's kind of a mind F, right? As water goes through this tight spot. Right where the pressure pickup is, it's gonna read light. And then as water slows down as it gets to the drop elbow on the rear of the rig or anything, pressure is actually going up So water, the same volume at a slower tube velocity has more kinetic energy than a than the same volume at a higher tube velocity.
Corley: You're talking to a guy who never got a friction loss question right on a tape. Dennis Lagueer: Yeah. Well it's more than most people need. We're working on it. It's it'll be fixed. Corley: Right on. That's the good news. That's the good news is it's becoming an industry it's becoming industry known. Dennis Lagueer: I yes, and I think once people are upset enough about it, it'll just become an industry standard. Corley: Love it. I love the fact that you are willing to fight for those things like true ID and now we gotta come up with a True discharge readings. Dennis Lagueer: Well, you know, I've always after I got hurt, I was retired, I just wanted a couple retainers and I remember shopping myself around like branding. Nobody nobody wanted me. Like an Eddie Bauer pump panel. We could have just Oh, the gear pump panel. It reads write, you know. Corley: Some leather insets and some leather. Dennis Lagueer: True panel. True panel. Corley: True panel. The gear, true panel. I love it, man. Looking forward, okay, Nick Barone wants to know, moving big water. My question is about using a hydrant valve. When should they be used? Dennis Lagueer: Right. that that's a that's a good question. You know, it's another one of those things like if you're a four-lay LDH department and you don't and you don't And you know that's that's Uncle Ray asking if the scrap's on, so I'll just say now. That'll mute my phone.
Corley: He's the la He's the one you're waiting on. Hey, Uncle Ray can interrupt the scrap anytime. Dennis Lagueer: So So You know what when do when do you want to use this? And it will be the it'll be dependent on your supply side. But when you I really think about it like your single family dwelling, if you look at NFPA 1710 brush and quote the stuff off the top of his head. I think there they say like 500 gallons a minute is all you need in a redundant water supply. It might be 400, don't quote me. Like brush knows the stuff left and right. commercials 800. So when you look at your residence, you look at your hydrant spacing and you go if you're in five inch hose and you look at 500 gallons a minute, whatever that would be in five inch hose, here's an old acron slide rule So 500 gallons a minute and 5 inch O's says 2 Psi. We know 5 inch O's is bigger than 5 inch, so it's less than 2 Psi. You could be like 700 feet away from a hydrant, and even a 30 PSI hydrant would still have 15 pounds left in the barrel moving 500 gallons a minute So the short answer is for your lower volume fires, it's almost never, right? And then so for your larger fires, it'll be often. Now that that might not be true for a department like DC with three inch hose, right? And older hydrants. They might drive away from a hydrant up a hill and the hydrant's only a 40 psi hydrant and they've driven 400 feet away from it and they're up They're uphill, so now you have head pressure and now they're trying to flow a couple inch and a half and it's 250 and the friction loss means something you're gonna have to you're gonna have to pump it. Right now The time you always, whether you have a four-way valve or hydrant valve or not, the time you always want to use them is multiple alarms on larger bodies of fire because remember when we were talking about pressure pickups and velocity as velocity goes up in the water mains right residual pressure goes down So that's why you see like one master stream is good, two master streams good, three master streams so sell.
Dennis Lagueer: Someone tries to flow a fourth master stream, no good master stream. streams, right? It doesn't mean the water's not available in the mains. It just means you have now used all the kinetic energy. The fire engineer that designed the water main system never expected the what the residual pressure to be your fire flow at major incidents and as a general rule of thumb if you're not placing Pumpers on hydrants at large water flow events, three Nearest hydrants, four Nearest hydrants, you're giving up about 50% of the available supply. So it's substantial. Corley: Wow. Dennis Lagueer: The and the other the other things is pumps push water. They don't pull water. So it's you know the big outlet on the hydrants the steamer for a reason, as you push it. Now that doesn't mean you have to have a four-way valve, you know, like Someone will probably correct me if I'm wrong, but Minneapolis and St. Paul, I think it's Minneapolis. Minneapolis always goes straight in Does a tank attack and the next engine either backs down or hand pulls and then they put a pump on the hydrant. San Francisco is another great example of the city that it does it actually I don't even think they have a rule for commercial fires. It's commercial, large body fire, any body of fire, the first two engine goes straight in and shall apply water. Right? It's trying to act like a time machine, whether it's a resident or a commercial, put time on the clock, reset, and then and then essentially the next engine parks on a hydrant and they hand stretch between those rigs. And that's one of the powerful things about like a Dual batter three inch. City of Seattle. for if the engine's within a hundred feet of the hydrant, they put it right on the hydrant. If it's not within a hundred feet of the hydrant, it's a major incident, they put a pump on the hydrant. Then you look at somebody like the East Coast, Camden, New Jersey, right? They have they have they have hydrant valves. So it's just a matter of physics. I think I've beat that question up enough.
Corley: I love it, but great, great, great answer. Thank you for it. I won't even go into three inch, five inch. I I'll I'll go to the audience questions instead of my questions. Hold on, coming at you. What are the Eddie J wants to know what are the main benefits of smooth bore on elevated master streams instead of automatic fogs? Dennis Lagueer: honestly it's probably not one that most people have heard. The automatic nozzles plus or minus 15 psi through its demand curve. So if you look at a curved chart And you look at like a 75 PSI nozzle, which is one of the major manufacturers making them with 75, it really means your actual nozzle pressure, actually. It's even worse than that. Your actual inlet pressure could be 60 psi and that's then you gotta minus all of the friction loss in the waterway itself because the fog nozzle is an appliance. you might end up having a discharge velocity of 60. So like an automatic nozzle at 80 and a smooth bore nozzle at 80 Do not equate to the same stream velocity. So that's number one. so you don't hit a true discharge pressure. number two is It's a solid column of water and less of it is exposed to the radiant heat column. So let me take you inside a building. Right? One of the things that people don't understand inside residence, like everybody like hence bladed pattern. Let's just talk patterns. Let's not talk manufacturing. Okay. Let's just say blade straight stream fog stream. And by the way, I don't really believe in the 30-degree fog. Somehow it's in literature. Let's call it realistically. No one's running them better than 20 degrees and then let's say solid stream all right so there the the fog nozzle and the straight stream it's an impingement baffle design So water goes through the center of it. There's two 90-degree turns. And doesn't really matter whether it's in the straight stream position or the fog stream position. You're hitting those impingements and that's the way it's forming. It's it's pattern, right? A space change is basically it's refigured in. So it's high turbulence, smaller droplets. And even in straight stream, as you go through a thermal column, it's more likely to be disrupted by wind and heat and radiant and radi and radiant heat in convection columns.
Dennis Lagueer: So it's more likely to be stripped away than a salt stream. So now talk about reach inside a compartment. And I've seen people now going around like tying Ropes to smoothbore nozzles and pulling them out pot and showing different angles and stuff. I kind of started doing that maybe four or five years ago at Water and the Fire and it's kind of It's kind of gotten out of that conference because people get there. It's not that I was trying to keep it secret or anything. I personally myself hadn't really come up with a Distance that I felt that a smoothborn nozzle will go in heat. Corley: Right, no, and even I was in that class Well one of them where you were stretching those hose you were stretching those ropes into the room and you said there's no way to know inside of a fire how far it actually goes. These are best guesses. Dennis Lagueer: Right. So I wanted to build like the UL had a stream study that was supposed to occur and essentially I wanted to build a gigantic oven horizontally and I basically wanted to apply water inside a giant oven at different velocities and volumes and just see how far they can go. I will tell you this that I know for sure that the vast majority of instructors are grossly underestimating true reach of a solid stream inside a heated environment. So so like let's just make this make perfect common sense here on the scrap. Let's say you go out to a drill ground and you have a seven eighths and it let's say it has sixty feet of reach and you put a you put an inch and an eighth right next to it has seventy feet of reach. reach all right so in a no heat environment let's say breakover is I don't know 30 versus 40 all right fair The vast majority of the reach credit two and a half gets past an inch and three quarter is post-breakover. No. So let me dig into this a little bit. If you have a solid stream and it's flowing along through a heated environment, And there's only a couple square feet of total surface area in that stick before it hits breakover. You see what I'm saying?
Corley: Yes. Dennis Lagueer: At 50 psi, it's traveling at 60 miles an hour So like, you know, if this ruler here is my solid stream, it's going through the room, right, and this is at 60 miles an hour. Do you expect to lose much volume when it's in its condensed state? Corley: Right Right, no. Dennis Lagueer: The answer is no. Right. Like I would almost argue that it would be within the measurement error at 1500 degrees Fahrenheit. Like you wouldn't even think about it losing any volume And we've had instructors for years say yeah 7 eight just evaporates in like 20 feet in a really high heat condition. And it's all these guys they're looking at thermal imaging and is that just anecdotal and and I have no idea where they got it from. I'll tell you what, the UL burnt some strip malls up in the coordinated attack study, and it was just an experimental commercial ad at the end, right? They really wanted to go in their commercial fire study didn't get funded by our federal government. Shame on the federal government. I'm sure it was written very nicely and submitted. One of the things that Lieutenant McCormick did before he left the FDNY is he allowed people to they change the engine book and it like bodega fires and small commercials. I don't know the exact definition They're allowed to stretch the inch and three-quarter now, right? And a lot of people like lost their mind over that. Well, we used a three-quarter inch in one of those fires. It was a 2,500 square foot unit. It was roughly 30 by 80. Mike Alt was on the on the team with the nozzles on it and they had a fuel package in the middle of the room and they were doing vertical ventilation. Andrew Andy Ruiz was there from LA City And they said they said, well what you what do you think, Dennis? You think that it's gonna have good reach? And I'm like, man, I I think from the front door they'll hit the back wall. And I knew the fuel package was in the middle, and I'm like, they're gonna have no problem collecting the fuel package So one of the things we told Mike is, hey, before you back out of there, if you start thinking you're in there and it's not going well, Ray said it, I said it, other people said it.
Dennis Lagueer: Hey, start low, sweep back and forth and come up. Because in a no-visibility environment, which we created in there and no tick, what could you easily miss with a dot? If you have a seven eights and you're running around there, what could you technically miss? Corley: Yeah. Dennis Lagueer: You could miss the fuel package. They missed the fuel package and missed the fuel package and missed the fuel package. And he said he was backing up and, you know, hopefully he'll listen to this so he can he can verify it. But then he went back and swept it And it went right out. So what was the next thing for me to do is in someone who's interested? I went straight in. What was I looking for on the back wall, Corley? Hit me. I was looking for is there any evidence that the stream made it past the fuel package And actually started coding the back wall. There was marks all over in the switch line past the fuel package. So when Kyle was dealing with the bladed pattern and we had him set up for a 50-foot advance and he was very worried That it wouldn't make the fuel package. I was like, I have zero fear here. Like all those drops are traveling about 60 miles an hour. They're all large. We're not gonna have any problems here. Too many people talk about Reach when they should be talking about coverage. What's the hardest thing to do inside a residential compartment, Corley?
Corley: Hardest thing to do Dennis Lagueer: I'll give you a seven eighths. You go in, it's a twenty by twenty room. Go. Corley: Yeah, you're hitting it with a laser beam. It's hard to cover Dennis Lagueer: It's your the the smooth bore stream is non-pre-distributed, right? So it's basically you have to use the surfaces to your advantage. Why do you start into the overhead? Corley: Break up and carry and flow. I mean yeah. Run and run. Dennis Lagueer: Oh you got you got a high heat condition, right? And frankly, it's one of one of the reasons you start in a high in the overhead in residentials, you expect a good amount of lift because what Cause the ceiling height's not that high. Would you expect a a lot of lift if the ceiling height was thirty feet? You think you could contract everything up there Corley: Yeah, you know if you're talking 30 feet, that's a whole different ballgame. Dennis Lagueer: Yeah, the answer's no, right? So we're so the residential high approach is to get water in the overhead, but more importantly, collect the ceiling and start what Well we got flowing your water down, getting it to fall out and coat all the walls. And then why are you working a pattern? What do you want to collect between you and the far wall? All the fuel packages, all the live load that is in front of you, right? So coverage. Remember what I said I wanted to talk about today. Volume, placement, and velocity. I don't want my nozzle pressure to be over 50 psi in a hand line. Frankly, I don't want to give up GPM for nozzle reaction, first off, but I already have a hard enough time keeping water where. Close to me. It's already traveling fast enough. I don't need my water to travel faster. In fact When I sent my video in, it's on my YouTube channel. When I sent my video into the fire attack study, and I had a pattern I was working, it came back, no discernible pattern, Corey. And I like what anyone who's watched me work a nozzle, I do these like really aggressive corkscrews. And I do I go into the overhead and then I bring the nozzle down really quick and I crash right in front of me in corkscrews If you do a series of corkscrews through a room in front of you, what are you going to collect?
Dennis Lagueer: You're going to collect the floor, you're probably going to collect part of the couch and back, and then if you work back with a series of corkscrews, you're probably going to collect the other. Other things. I see two problems quite often when I see videos on the internet. And James Nisbet, super great guy. He's out podcasting. I love seeing people move. The next generation should exceed the previous generation's knowledge base, right? Jay Bonifield. NISBET, all these guys that are out there that are nerding it up, Kyle Romagus are reading it and they're they're they're they're moving forward. He posted a thing the ending company in directions from Clackamas, which is a dialed in fire department They're going to the prop. And it's like into the overhead, into the overhead, into the overhead, into the overhead, room to room to room to room. And I'm like, I'm not going to Comment on this without calling them first. Like I call them, I said, Hey man I can't let that not go without a call because everybody in the comments is like, it's the greatest thing, it's so awesome, it's awesome, this is cool. Man, they're really nailing it. And all I saw was like, that's horrible suppression. Like they went into a room, worked the overhead, backed out, and went down the hallway. What did they miss? They miss a fuel package. Right? They miss most of the fuel package. You you execute how you what. Train. You execute how you train. So like back to patterns, people go like, what are you trying to solve with a bladed pattern? By the way, it's not what I'm trying to solve. I didn't even like it I just want to do the wildland stuff. I was like, I I don't know if it's going to be inside. The more I see people use it, the more it solves the coverage and all of the things You know, some people that shall remain nameless want wall ceiling floor wall. I want squash goes and corkscrews Ray was kind of a side-to-side guy. And notice some of the stuff that Ray did way back in the day, 20 years ago, the bounce in the hallway, the pulling the stream back, right? Let me give you an example where you should never start into the overhead. Who has multiple family dwelling fires
Corley: Yeah, yeah, absolutely. Dennis Lagueer: All right, clean hallway, clean hallway, fire rated door. And the the irons are working on it. It swings open and it's not a back bedroom fire. It's what? It's an open floor plan, kitchen completely off. L-shaped couch straight in front of you and you're in the the door is the nozzle. Where should you spend a lot of time? Not in the overhead. You might want to start there for a second, but where are you? Where have you been warped to? Because of the building features and the construction, technically, what are you right next door to You're this you're at the seat of the fire. The fuel package is right in front of you. There's a great video from the UL Burns in Cobb County where they swung the door open and it's exactly that. The guy spends time the overhead and he just looked like a Christmas tree. in front of the door until he lowers the nozzle. Right? So coverage is super, super important. So back to master streams and automatic nozzles. Corley: Full circle. I like it. Dennis Lagueer: We'll circle all the way back. The constant gallonage nozzle means you're stuck at a single speed. And one of the most valuable things that you can get out of a smooth bore nozzle that is correctly sized for master stream development is velocity. And Matt Scallion, who's not on the circuit anymore, but was kind of Kurt Isaacson's right-hand man, I wish I'd Come up with something so smooth, but he says I like my inside water slow and I like my outside water fast. You want to get it through your thermal column. By the way, if it's going too far, what can you do with a fixed orifice nozzle? What does a fixed orface nozzle not do?
Corley: Adjust. Dennis Lagueer: It doesn't preserve reach. What's an automatic nozzle do? It always preserves reach. Who's had a master stream that's going over your objective? Corley: Yeah. Dennis Lagueer: And what happens when you turn down the throttle, you try to reduce nozzle pressure on an automatic nozzle? What's it do? It keeps reach. Corley: Yeah, it keeps doing what it's doing. Dennis Lagueer: Yeah. I've multiply manipulated tip pressure to my advantage. All right. And by the way, I think if you can hit what you're trying to hit Nozzle pressures below 100 psi for master streams are bullshit. There's really no need to. I would rather have a smaller tip. Remember, back to volume. You're a chief. Let's say you have three hydrants and each hydrant's good for 1500 gallons a minute and you have a large fire. So that's 4,500. 4,500 gallons when you're at zero for the scene. Corley: Tracking so far. Dennis Lagueer: Okay. Would you rather have Three 800 gallons a minute, really nice, high pressure master streams doing work. Remember, for every hundred gallons a minute that's delivered to the service It's about a million BTUs per minute. So that would be each one's capable of suppressing 8 million BTUs per minute, as long as you're hitting what's burning And that would leave you what? 2,000 gallons a minute for what? Hand lines and little monitors and stuff. Have you been to the fire where you look around and there's some numbnut? With an automatic nozzle that had a high compound pressure. He keeps throttling up. What's that automatic nozzle doing? It's greedy It's gotta just keep taking, keep taking, keep taking. Then you want one what for your exposure? One two and a half inch hose line. What do you not have, Chief? No water. You have no water. I don't need a 1250 or 1500 gallon a minute automatic nozzle not doing anything anyway. I want a I want a two and a half inch handle. I'm shaving the house that's not on fire yet
Corley: I love it. Hey, brother, this is amazing. I wish I could keep up. The questions are awesome. I have no answers for you half the time. And I think actually, yeah, Mark Alone has it best. Cordy, stop buffering Absolutely. Man, I'm trying to keep up. I'm trying to, I'm trying to just soft serve Dennis. So keep the questions coming. It's awesome. I will do my best. But absolutely. John Novak, he wants to know, where did the recommended nozzle reaction of 69 PSI come from or what was it based on? Dennis Lagueer: So he he meant 69 pounds, right? When by recommended, I think he's talking about inch. I'm just guessing, inch and three, it's a 1516, it's 70 pounds nozzle reaction You know, the 15th 16th nozzle, obviously, you know, the origin story is the city of New York. They were an inch and a half, they were an inch and three quarter, and then they made 188. Somebody must have overbore it. It's mentioned in Fornel's book is like you know half the body weight of the average fireman that can't be true anymore, right? So like you know there I don't think it's like another one of those things where you know back to what I want to talk about volume placement and velocity the 7-8 inch flow, the 160 at 50, that's 63 pounds technically, right? And they just did a research study, Dak, I will mess up his last name. From University of Illinois, they did a a nozzle kickback study that they quoted Aaron and in myself and a few others and Sammy Vega was was involved in it and it talked about the bend in the hose and if you take one of my spec and layout classes I talk about the 72 inch nozzle bite like Brian Brush for example all those videos of him doing like a handstand with two and a half and it's flowing or has it just on his boot That's because there's a certain amount of water mass and material mass and weight in the last 72 inches that is counteracting the 99 pounds nozzle reaction of an inch and an eighth. And I I believe he's a big fan of the inch and three sixteenth, which is at 50 is really 110 pounds. If you take the same nozzle and you put an inch and eighth on True ID two and a half made by Key, people are gonna say.
Dennis Lagueer: They're gonna pedo it, they're gonna have a calibrated flow meter and say, hey, it's the same volume. Why does it feel like so much more nozzle reaction? There's actually less weight In your counterbalance, there's less water per foot, less material per foot. It's nice and stiff. You know, some people might say that it's too stiff. you know, and I I I I'm like, you know, you look at SuperTue and at inch and an eighth, Mercedes products a little more whippy. Like you get you can go back and forth. I I personally think once you shrink down the diameter and you're trying to go for that 250 flow, I was focused on giving as much of a pipe as possible because what's very important. Placement and how do you get placement? You get placement through balance balance of all of these things, right? Weight of the hose. So you know, I know Key's a sponsor and I obviously done consulting work. form. Sniper was made because True ID didn't fold extremely well. Is True ID a bad hose? Keith Morris is like, I love it. You can grab it with gloved hands. He's like, I don't want hose to lay flat. I like when you throw down, you can see all ears. Another guy from the DC Beltway might not like it because doesn't Fit flat on their shoulder, right? so these are like baking cakes and recipes that 70 pounds I'll say is the highest Nozzle reaction I see for a single person to be able to flow and move in advance. If you if you're a two-person engine company, I'd rather have you at 150 gallons a minute out of a seven eighths than 180 gallons a minute out of a 1516 because I think you'll flow and move, you'll apply more water, back to that amount of water Delivered. But it's not only that, it's coverage. Are you doing your coverage appropriately? and This device that I did the turbo, right? And I think I've made some people upset with this device. I'm always trying to come up with solutions for people. I realize that there's a lot of the fire service that only has a two-person engine company. Would you say that's fair?
Corley: That's fair. Dennis Lagueer: Okay. So if what's half a 50, Corley? Corley: I can do this one. 25, baby. Dennis Lagueer: And that's fifty percent, right? It's 50%. So 75 is 50% greater than 25. If you put this on whatever nozzle manufacturer you want, it's designed to create 25 pounds friction loss at 160. You've added 50% more mechanical back pressure. If you're a two-person engine company, who's getting your kinks? Corley: Yeah. Nobody nobody. Nobody. Dennis Lagueer: When you ch when you charge Dallas Great Fire Department, I have nothing negative to say about them. they got some true ID. There's a famous video out there of some guys getting their They're their their gear all saturated on a porch and heated up because they had a bunch of kinks on their initial charge. I'll give you a couple advice on true true true ID I love it. It's a great product. You better charge it extremely aggressive. And you should grip it and rip it open. My personal preference is to charge an RPM Why would you want to charge an RPM instead of PSI, Corley? Corley: Just the volume? What are we talking? Dennis Lagueer: So it's the pressure set on the governor. What would you want it in cruise control? Let's say you know you need to pump at 110.
Corley: I feel like I'm being quizzed for a promotion. Dennis Lagueer: Yeah, I know. It's always that's how I run my classes, and you unfortunately are on the other side of the cruise. Corley: I'm the only student there. Dennis Lagueer: You're the only student Corley: Go ahead. Go ahead. Dennis Lagueer: If you put it in cruise control and it's sensing pressure and it runs into the first couple kinks and then it it sends a pressure signal back hydraulically Right? Right. Let's say it runs in a couple kinks and you're not getting water. You set it at 135. 35 plus 35, 70 plus you set it at 130. And there's a cut you the guy didn't lay it out super smooth. It senses 130 pounds back to the panel. What's it gonna do to the RPM of the motor? Yeah, it's gonna be kind of throttle down. Right. Who's been there? I know there's been people on this radio that are listening. that have been going around knocking out kinks when the rigs are essentially idle. Because if you have no water at the nozzle and you set it for 110 Let's say Key Combat Ready or any very large host, Mercedes EXO or Pond Gladiator. It's a very big tube, right? So you have a very low pump discharge pressure. Let's say you only need to pump at 90, right? So it's 20 plus 20 is 90. So you put it in PSI mode. You hit 90, it hits the first two crappy little kinks. It gets 90 back to the panel. Who's been there as you're knocking kinks out? The water's just kind of slowly, lazily. Oh, it's got to the next kink. I gotta go get it.
Corley: Very lazy, yeah Dennis Lagueer: Right? That's because you charged in PSI and not RPM. And by the way, who are you protecting? What's the PSI mode for? Corley: No. Dennis Lagueer: It's to protect the second person on the second line. If you pull up and you're making your initial charge and you've charged in PSI, I would argue you're doing it wrong. Corley: Wow. No, I didn't even thought about it. I mean, I I don't think a lot of people have thought about it. It's a wow. Okay. I failed my test, everyone. Dennis Lagueer: So the turbo, back to the turbo. Turbo. It you get 21 feet per second. It doesn't screw up the Freeman ratio. It it creates an environment where you have 50% more mechanical back pressure back to the pump. Have you ever run a pump coral and had to gate it? You get 70 PSI hydrant? Imagine most of the time you're never gonna have to gate the pump again. So if you show up, you charge an RPM once they get pressure and you go to 135, if your net pump pressure is below your hydrant pressure idle. Yo the governor will always work. So it fixes a lot of the pump pressure issues around the g governor If you're not chasing kinks and you're not gating the rig, by the way, we talked about earlier in this show, is your pump panel going to read properly when it's gated based on the way they're plumbed now.
Corley: No, the way they're plumbed now, no, and that's a that's a huge takeaway. Dennis Lagueer: No, so guess what? Is it easier for me to go around the country and fix everyone's pump panel or is it easier for me to do this? And by the way, most people don't have a four-person engine company or a five-person engine company. company. No, I'm this fixes a lot of problems. Like it you like I I'm not interested in being involved in stuff that doesn't fix material problems. And I think that's a good thing. Honestly, I think, you know, Key Firos might be like semi-flustered with me because like I'm using their product. And I'm like, hey, sniper with this is the next best thing. And then I go, with the bladed nozzle, it's even better, right? And they go like, well, you're saying something about our product. It is, it's their company, it's their product. I could say the same thing, cracking EXO or whatever. Does a low pressure hose like Sniper need 25 pounds of back pressure to work properly? No, but if somebody takes this device and puts it on Eco 10 or 8D from SnapTight and says I never have to buy premium hose again I think the hose manufacturers have failed. What's some of the other important aspects of premium hose, Corley, other than low pressure
Corley: Well it's a kink resistance in theory. Dennis Lagueer: Kink resistance. So it's it's a leg up. So anything this does to help eco ten, it does the same or better to something like sniper. But what else It's a heavier hose that's gonna burn through less. It's gonna get less damage. You can train with it. Right? Corley: Stolen called better it's it's better hose overall. Dennis Lagueer: Yeah, I don't know. We could come up with an analogy. I'm not going to come up with it. It's an equal level playing field for all of the small handline spectrum. And, you know, I'm going to tell you right now, there's going to be a two and a half inch version because I know all of the agency, why does Dennis not like two-inch hose, Corley? Corley: Why does who? You? Dennis Lagueer: Yeah. Corley: I'm actually I get to ask you back, why do you not like two inch hose? Dennis Lagueer: Because it's super whippy. You can't get a good commercial flow out of it. You can't get a good 250 out of it I'm not really good at flowing below 250. Bill Guston called me the year after MetroDade Miami went to two-inch combat ready with two and a half. He wrote that beautiful article with the inch and an eighth tip, and he said, hey, what I'm really looking for is between 40 and 45. I'm not looking I'm looking for 250 ish I'm not looking for 265 because it's a bear it's a bear with at 265 the nozzle wanna hit you in the face Shannon Stone same guy He calls me up a year and a half later. He's like, you mffer. Now there's true ID two and a quarter. It worked with an inch and an eighth. And it's actually at a lower friction loss. He's like, look, look what look what you've done. Well, I can go back now and whether it's Keys product or someone else's product, there's a lot of enhanced two inch O's out there that's 2. 2 inches combat ready Ish, probably gladiator two inch. Those engine companies that only have three members on it that can now add a little back pressure to their two-inch line and flow a true 250. It's gonna be a materially positive thing for the American Fire Service. That's called progress
Corley: No, I love it. I love it. And here's what I'll say. And one of the best things I love about the turbo is is I think the bait the the the major holdup of departments, organizations moving forward with a with a proper attack package. And that is mating a good hose with a good nozzle and understanding the the combination. That a lot of people just slap a smooth bore on the hose they have and they're like, hey, this kicks me in the face and I don't like it. You know what I'm saying? And that's that's just ignorance that exists But what the turbo does is it allows people to slap this in between that that low quality hose and that nozzle and then have have it perform as it should, which is a nice stop gap. But it does not mean that it is premium hose. Dennis Lagueer: Yes. And my s my suggestion to anyone that you want a hose and nozzle study out there you know that is in a large department or in a department that can't or by the way my official position would be you gotta address hosts first Right? And for for example, I liked true ID better than sniper, you know, cuz just because I like how stiff it is. It does I actually wanted it, and you can talk to people that originally designed it. I wanted it to be 40 PSI per 100. 40 plus 40 is 80 plus 50. Right, we're at 130. Why did I want it to be 130? Most hydrants are between 60 and 80. You add 50, that gets rid of your having to gait We couldn't get there. I wanted to put little speed bumps in the rubber liner. Do anything, you know, like make it make it have more friction loss, right? Friction loss Friction loss and tube velocity are non-correlated at the same diameter based on liner smoothness. By the way, liner smoothness is not even anything anyone talks about.
Corley: Did you just hear what you said? Dennis Lagueer: Yeah Yeah. But my official position would be if you're one of those fire departments like San Diego or LA City's doing a hose and nozzle study, Portland's in In hose that doesn't really work well with 50 PSI nozzles. So they're in the they're in the dreaded 150 at 75. Why do I call it the one dreaded 150 at 75? It fixes a lot of hose problems, but what does it not do? It has 75 pounds nozzle reaction, 70 pounds oxy reaction. So what is it often spaled down? So now you're under 150. Corley: Now you're not even getting your water flow. Dennis Lagueer: You put this in any manufacturer's 7. 8s or 160 at 50 or 150 at 50 or whatever. You put this in the back. Do you think a 150 at 75 nozzle should ever be sold again? Wow, it's it's been made obsolete. Corley: Yeah. Dennis Lagueer: It's dead. You can do a graphic, you can do a patch with the 150 and 75 nozzle, which by the way was the most popular nozzle. Fog nozzle in America. Chris Martin or those guys could weigh in sales figures. They say the 160 to 50 out sales them now. But right now In the American fire service, there's more 150s at 75s going to jobs than there are low pressure fog nozzles. Why? Because of hose issues This fixes it. But back to my position. If you're doing a hose and nozzle study, what's allowed now is you can. Keep your crappy hose, buy a single length of good hose, buy a turbo, buy a nozzle that makes sense Whether it's 15, 16th, or 7-8s, use this device and then ride a nice host spec and through attrition, what's a fire department should buy every year, a little bit every year
Corley: Somehow, well every yeah, depending on your time. Dennis Lagueer: Every few years depends how big of a fire department you are. Corley: So in other words, we're every 10 we replace everything. Dennis Lagueer: But yeah Through attrition, you can get to where you need to go, which is amazing. Which is amazing. Corley: No, and to the and and all those all those other qualities besides flow that we're talking about that matter Dennis Lagueer: Volume placement and velocity, right? You know, volume placement of the the turbo is pro-volume because it's anti-kink How many kinks do you think you've laid a hand on or seen in your career, Corley? Corley: Kinks that I've I've personally just as a chief, I don't know. I couldn't even count just as a chief trying to take out kinks Dennis Lagueer: Right, so and then think of your entire fire department or think of a gigantic fire department. Think of a huge department like like New York City or something like that, right? They're stretching from their stretch bed how many trips they've had in their in entire thing. Uncount uncounting. If they uncount to this, which I don't think they will, but if I I had any drudgers here, I'd say it would be smart. Guess what? There would be 50% less kinks. From this moment forward, there would be 50% less kinks. So if they did 2 million kinks in the last 150 years, there would only be a million kinks in the next 150 years. fifty years. That means something.
Corley: It's a powerful argument. A powerful argument. I got this one coming at you from Mark Alone, who has been busting my chops a little bit in the chat but that's okay Dennis do you see 1. 5 inch attack lines making a comeback due to all of the advances in hose construction Dennis Lagueer: All right, so this is a you know this is another thing like it's covered in my class. you know like and and and I totally get I I was in inch and a half hose at 95 GPM roughly at 100 psi for a number of years, both in Oakland and in another department before I got to Oakland. Everybody likes it's only about 50 pounds nozzle reaction. There's almost no kinks. could have I made this through 100 psi back, I mean 50 psi back pressure. One of the things 100 psi back pressure is unlikely to kink, Corley, but once it kinks, what's it exclude more of? Why? It's a tighter kink. It's one of those things. This porge is too hot. This porge is too cold. This porridge is just right. Right? Like, you know, we can get crazy with this stuff. We can get crazy with this stuff Inch and a half hose, modern inch and a half hose is 1. 65 drive plug at the factory, Mercedes. true ID inch and a half O's, whatever they call it, plugs at the factory one six five. I think it's EXO. And when you charge it, it has a tenth of an inch expansion factor So it's 1. 75. They're like, look at how low the friction loss is in it. Montgomery County uses it in the beltway. And it's really whippy. And then you try to get 150 gallons a minute through it And it's it's too whippy at a 50 PSI back pressure. So guess what nozzle do they're in? The dreaded 150 at 75. So now they're trying to get 150 out of it and they have 75. They got to choke up on it. If you choke up on it, do you have good placement?
Corley: No. Dennis Lagueer: You don't have good placement. Now what you can do, right, on that hose, you could put a turbo and you could do a 7-8. Guess what? The turbo allows the 7-8 to be at what pressure and still not whip. Like 40 pounds. You can have a 7-8 at 40 pounds. You still have an extra 20 pounds of back pressure back this way. So that video I did with me with Without me getting sued, you know, Michael Avishon owns the company, North American Fire. I I he's a true OG of the hose deal. Polly Tough It's inch and a half hose, it's a lightweight hose. With me, that video I put out with the turbo, with me messing around with it, it wasn't because I was advocating for it. I was trying to show someone how powerful the technology is, right? and why I stay Well, I don't think it'll bring inch and a half hose back is the nominal weight difference between one point Seven and one point eight at a tenth of an inch. Like we could do the calculation. It's gonna be like maybe a gallon or two gallons of water over over a hundred feet. We're talking about like eight pounds. It's not the difference between two and a quarter and two and three quarter. And then there's a lot of additional friction loss. And then the water is going to be traveling extremely violently through the hose, which is going to bring sidewall pressure down. So there is a balance. Now, that being said, if I worked in Montgomery County and I had control of the purse strings, I'd want to get rid of that 155 150 at 75 nozzle and I would want to buy a back pressure device. and I would want to drop my nozzle pressure, get the nozzle out in front of me and get water mapping, would it make their existing inch and a half spec work better? Absolutely. But you could say that about a bladed pattern too. A bladed pattern in a residential compartment is always going to capture the couch quicker. It's always going to be I felt like it was, I had so much bias around it, Corley, that I didn't realize what. Why are we working patterns inside residential compartments?
Corley: Water placement. I mean that's what we're working on. Dennis Lagueer: Well, I is it I got it I got it listed like I have this slide, the attack package disclaimer because so many people's feelings were heard of. O patterns, D patterns, T patterns, D Z O why are the why are there all these discussions? Cork through patterns, why my patterns not technically a pattern? What are the patterns granting you access to? Coverage. Coverage. It's inside the box. It's dead center of the box A pattern that enhances coverage. It ain't outside the box. It's fucking ground zero. It's dead center. Corley: No. Yeah, I'm I'm trying to catch you up with our Kyle Romaga said Well, he's talking about the turbo there. He said to smash the stream and break it up. That is the reason for the patterns. The TZNO is to smash the stream and break it up. Once it hits the surfaces. Of course. Dennis Lagueer: Let's take have you ever advanced a line to like a master closet? Like or a smaller room? Corley: Sure, sure. Dennis Lagueer: What's the quickest way to just make sure you've knocked the piss out of everything in there? Half bail. Corley: Okay. Dennis Lagueer: I don't know if I've if you're in a high-rise or an office space and it's cubicles And you you get in there and you start working a pattern, you're and you're going down that little cubicle hallway, right? And I would be working my pattern left to right because I'm trying to pick up what Trying to pick up all those door edges on my advance. I'm not gonna work the overhead very much in a commercial because it's the cubicles that are on fire and what's above me A black void of piping and fucking drop ceilings and wire chases. There's nothing to extinguish up there. It's nothing but a hydraulic break on my water. So now If I get to a cubicle, a bunch of cubicles that are on fire, when I turn into the cubicle, am I gonna leave my Inchina 8th nozzle full open? Does that make any sense?
Corley: I mean I'll be honest with you, that's probably what I did. You know. Dennis Lagueer: But does it make any sense? Corley: But I was fired up. But I get it. No, no, it might not be the most tactical best decision, but it might be what I did I don't know if I would have half-billed at that point. I might now with a little more knowledge. Dennis Lagueer: Now go to an RV fire outside or a deck fire outside or something like that. Right? And some fire departments run their smoothbore nozzles on their car lines or whatever. What do you see guys do often? They have visual cue. They're outside. They got the RV on fire. They use what? The reach of the stream to like get it out, get some in the windows or whatever. What's the first thing they do They have bail when they go up, when they're putting the nozzle inside and stuff, it's all about coverage. A bladed pattern gives you coverage at full volume. Corley: Hmm No, I I can't argue, brother. I can't argue. And and there's a lot of people talking about it. Well, I'll bring up a couple things that I've heard over and over, and I'm sure you've heard them enough. But one is like the turbo. You got the turbo. Yep. It's got those veins in it. People bring it up all the time. All the time about the veins. Yep. Talk about 'em.
Dennis Lagueer: Well, you know, I I didn't come up with the shape a hydraulic program did. One of the things that I wanted to make sure is it didn't take away a lot of the reach of a solid stream, you know, like I you know I think that's very important, you know, especially when you're applying water from the out. I think reach in the two and a half inch hand line is vastly more important than reach in the small in the small in the small hand line. mainly for applying water from the exterior to the interior of commercial spaces and breakover and stuff like that. So the veins are in there to basically create some eddies and have the water become more laminar and less turbulent again because it's going through this restricted orifice. And You know, like you wouldn't want to add friction loss to a standpipe attack package. And unless you did like an infrastructure survey and all your outlets are 150 or greater. Hey, have at it. This is not what this is device is for. It's for rig stretches. And essentially it's to make rig stretches what? Save more lives and property. Less kinks, easier to handle Imagine one thing that people get really, you can tell the difference between true ID and sniper at 50 pounds nozzle pressure. When you're the backup and you're feeding it forward. Sure, I need a stiffer hose. Now sniper's good, it's just not as stiff, right? So this makes that backup man's job a little bit easier But again, like something like sniper, you don't need this, but then is the guy prop properly pumping it? And you could say that about everyone's house. Now back to the the deals. Is it a clogging issue, right? So I talked to Greg.
Corley: I think that's everybody's main concern because it's so long, so long people said, hey, you know Dennis Lagueer: I was against stream straighteners. By the way, Ray and I have been friends a long time. He used to love stream straighteners. And I'm like, Ray, man, the first thing you do is break the stream up. Why do you? He's like, I just like the way it looks. Like, you know, I think it's important on Reach. And I'm like. You know, like I was ordering the smallest tip for Oakland, and we had older shutoffs that were split balls. I didn't even care. Like you know the whole split ball deals like I was like for a for the infantry quarter line it really like the little bit of imperceptible difference like I was like, whatever, we'll we'll I rather get the nozzles out and we'll figure we'll figure it out as it as it goes. So back to the clogging deal. It'll pass a quarter. A 1516 tip can't pass a quarter. And then it'll pass a 5. 8 inch bearing. And a 5-8 inch bearing, the impeller of a 10 12 inch or smaller impeller whether it's water is darley or whatever that cross section it won't pass more than a 5 eighths inch bearing so in other words there's nothing that can come through the pump that can't Can't go through this. I was very deliberate when we designed it.
Corley: Right. Dennis Lagueer: you know, and and that's it. Now people will go like, what about a potato chip bag? Or what about a glove or what about, what about, what about, right? And And I mean we can play that game all day long. It's not designed to go on stand pipe systems. You know, like it's not. Now, here's a little bit of a min F for you. Guess what's in a lot of Stamp Pipe systems? PRVs. Right? Corley: No, without a doubt. Dennis Lagueer: Okay, how how how open do PRVs get, bro? Corley: Oh brother, you're way out of my wheelhouse at this point. Tiny. Like quarter hits, you saying three-eighths. Dennis Lagueer: So what where are we really worried about debris and standpipes? What type of stamp pipe systems? Corley: No, no, I'm again, I'm just throwing at you the things that people have said. Oh no. I'm just you I I know you have heard it like you've heard it dozens of times. Dennis Lagueer: Actually, I'm not busting your balls. This is beyond the turbo. If you're ever interacting with the dry standpipe system That's when you really want to pay attention to your flush and you want you and you want it to be laminar. Why do you want it if it's a dry standpipe system? The first thing I would do is open it up when I would get there and lay my tools out And if I had a gate valve, I would have put it on there. I want first water to come out of my outlet. If I can beat the guy charging it, why? I want my debris to come out And then when you're climbing up the stairs on a dry stamp pipe system, what does the attack crew have to do on the way up You gotta visualize every stamp pipe outlet. Is it capped? Is it not capped? Is the stem open or shut? My engine company carried extra caps. Because like sometimes you'd see a stem that's open and it's missing what? It's missing the handwheel. So what am I gonna do? Am I gonna sit there with my pipe wrench and try to assign a firefighter to close it? Or I'm just gonna screw a cap on there and move on.
Corley: Gotcha. Right? So it's why so Dennis Lagueer: Why do we flush wet barrel hydrants? Now dry barrel hydrant, why are you supposed to open it gently? Go to the largest outlet, lowest outlet, and only fill the nozzle halfway. Why are you supposed to gently flush it first? Corley: We don't have a dry barrel. I've never even heard of this. You're teaching me stuff right now. Dennis Lagueer: So dry barrel, a dry barrel hydrant is the one the hydrant that's below the free line. We have a dry hydrant. So you probably have that wet barrels, west coast, temperate climates, right? The the worry is that a kid puts what in there Debris like matchbox cars, gloves, potato chips, bags. So you don't want to aggressively flex your drive-rail hydrants because where does all that debris go? To the top of the bonnet To the top of the bonnet. By the way, what else? Ice. If you open a dry barrel hydrant, ice floats, it can get stuck at the top of the bonnet. You shut it down, it's too big to leave You hook up your flowing lines, that ice comes up and blocks the hydrant. You get low intake pressure. What happens? Your rig goes to idle. I personally think That may have been a contributing fact factor of Black Sunday. Because they could never get the rigs to reproduce what occurred there. And it was an extremely cold day. They said they might have had ice in the wine. They had a rig go back to idle several times. And the only way I could reproduce it was put a piece of styrofoam in a dry barrel hydrant. Like I went out and did it just because I was curious Right? I was just like, why would a rig go to idle? Why couldn't they reproduce this? It had to be on the intake side, right? So I was trying to think, like, by the way, do I have any freezing hydro issues in the city of Oakland We had three dry barrel hydrants in the entire city. So back to standpipes. So now you're flushing a dry barrel system gent dry system gently. You want to get all the debris out of it. How long do you flush other standpipe operations? Are you looking for clean water? You know that black water that comes out with all that when it when is clear clear enough?
Dennis Lagueer: Can black water put out black fire, as Ray would say. Corley: Right. Dennis Lagueer: You're you're not actually you're looking for pressure and volume out You're not really trying to get all the scale out. What what does a stamp pipe nozzle have to be? Self-flushing And it doesn't have to be self-swecking for the big debris. It has to be self-fleshing for the scale. That's another thing around Like Brent Brooks was like, oh yeah, a head nozzle. It can be standpipe approved. And I was like, well, that's true. Like that's a bladed nozzle. It has it's a it's a it's just a hole you can look through So it's a self-flushing nozzle. Corley: Right on. Dennis Lagueer: So. Corley: I love it, brother. Man, again, yeah, absolutely an education and people are trying to do that. Dennis Lagueer: I'm sure there's more questions. Corley: Oh, there's a ton. But I'm gonna go to one of my favorites, which is what book or books do you think firefighters should be reading? Doesn't have to be firefighting books. It can be anything, but what books do you think firefighters should be reading? It's one of my favorite questions I ask. Dennis Lagueer: Yeah, it's it it's that's that's a that's a tough that's a tough one for me. You know, like I have standards that I I really really really like. I mean Clark Principle of Firefighting Practices, it's out of print, but it's really good. I think most people read John John Norman's book, you know.
Corley: yeah. Dennis Lagueer: The Blue Book and John Norman's I don't care what edition The Blue Books is a very valuable book that I think probably doesn't get discussed enough. Corley: No, I'm with you. Willie Clark and John Norman, is that what you're going with? I don't know what I'm gonna cut. I don't want to cut you off. Dennis Lagueer: No, those are those are two and like I think that Those two books are extreme extremely valuable. You know and Dave Fresnel he does he does have the the reprint kind of like in review. I don't know if fire engineering will put it out you know, I don't know if it's up to date enough to them, but obviously, you know, Firestream and Practices by Fornel. But these are probably things that I've said before. What would be like something new you know, like I I'll think give me a minute, I'll think about it. I'm trying to think of anything new that I've read that might be might be a worthwhile endeavor. volume. Let's go back. Let's go back to volume in large spaces, right? So I think what's not being talked about a lot on the fire ground is geometric shapes of buildings. Like if you had like an L-shaped building, let's say you had Like a shop and it was like 50, let's say 60, 60 by 100 and 60 by 100. And it's like an L shape. And you have You have signs of fire throughout and you know it's one space. It would probably be better to Enter on the ends, right? The two initial hand lines should apply through the Mandors at the two ends of the L, and then have a third one pick up the center Right, if there was a man door in the center. And the reasons you'd start at the ends first because your stream would be narrow and long, and the center would be just the the piece that you're missing. So like Kind of like imagine gigantic grass fields and you're trying to get everything wet. A lot of the opposing handline stuff that is in dogma around residential fires is inappropriate thought processes on commercial fire ground. Like you really, you want to look at the building more holistically. And typically, I would argue that you want to start where you think the origin is and work the closest.
Dennis Lagueer: entry to that. And you know, these are hard lessons learned. Like if you look at like the Charleston 9 or other fires where and that's a really interesting building because people don't realize this it was added on to so many times that it just stayed below the sprinkler code the entire time but you know like If you can't, if you can't enter from two different spots. So like a strip mall with a lot of fire coming out the front. Have you ever seen that smooth bore pattern that's going through a large vent point ignition and there's just a continuous amount of fire coming out of there? True. And it's like a guy kind of like resting there and there's fire coming out. Have you ever thought that he might have actually put the fire out that he's hitting? Well think about it. If you're in a smooth. Corley: I love playing hypothetical here, but no, I haven't. Dennis Lagueer: If it if you're in an inch and an eighth And you have like, let's say, 80 feet of reach, and a guy gets up 20 feet from the window and he's going back and forth, back and forth, he might have put out the back 40. And that vent point ignition, what are smooth bore nozzles extremely poor at? In a non-distributive environment, it's up to the nozzleman to be the sprinkler head. That's why I do all that training with the Slow Z left and right all the way down. And then I say whip it as hard as you can on the way back because I'm trying to get that water to fall out early. And then I learned it from Jeff. I think he teaches it mainly as an aid on nozzle reaction moving forward, but I think half bailing moving forward gets a predistribution where you're going next. So here, Chief, at your next strip wall fire, right, when you have a guy with a handline up front, what's that little stem wall prevent That memo prevents you collecting. Getting low. Getting low. So the first line, bring two couplings forward, bring the nozzle back about breakover distance. So let's say you have 80 feet of reach on the drill ground, break over at 40. So get back about 30 feet, the initial nozzle. What's good about that is their gear getting saturated. No, are they in the collapse zone?
Dennis Lagueer: Probably not. Corley: Probably are. Dennis Lagueer: Right? Where is their water initially going to enter the building? At or near breakover, what's their initial extinguishment? Corley: So it's gonna it's gonna hit and break down, yeah. Dennis Lagueer: Right where they want to go next, right? So now you're the second engine engine on scene, you're pulling your two and a half to support that two and a half. Let's say this is the kind of building you can't get around to the Charlie side or there's attached exposures in their firewalls. Should that nozzle man line his nozzle right up next to that guy's nozzle No. He should he should he's that water's entering at breakover. Where should he be? Or she? They should be like 20 feet forward because that water is gonna fall where in the back of the strip mall. So they should be like this. They shouldn't be together. They should be staggered They should be staggered. You're looking for a different footprint of extinguishment. Yeah, I know it's it's gonna sound like I'm just harping, so Back to patterns, back to movements and stuff. I think the bladed pattern is gonna be a heavy hitter in non-distributed environments. I mean think of a paper aisle. Like if you went to a deck fire on the back of someone's house and you had lots of decking on fire, right? We've we've all been there, right? You're using the reach of the stream. You're like Tasmanium Devil. You're knocking all around. Once you get the deck mainly extinguished and you get up on it. Are you leaving that smooth board nozzle wide open?
Corley: No. No. Dennis Lagueer: No, you're like half bail, let's get everything. Did it break the sliding glass window? Do we need to get back inside? My advice for this on Charlie's side decks is always to drop the line and deploy another line for two reasons. I think The it's too hard to re-deploy a line of the alpha side and the other thing is what's that line actually technically there doing? It's almost a safety, especially if it's broken one of those windows and the fires got inside. You have a Charlie line that is charged and present Right? The engineer could have stretched another one. But back to this deck, right? Imagine the same exact fire with a concentrated edge where you could just go swipe, swipe, swipe, swipe, swipe. and get a whole bunch of the deck. Now go inside in a place where your stream is not going to hit a surface. The nearest surface your stream's going to hit, the wall is way far away, and you have a bunch of racking on fire. Right? The bladed pattern. Alright, not everyone's gonna have a bladed pattern. How can we how can we get some of this without a bladed pattern? Alright, you go in with a two and a half and you knock the piss out of it. Right? And you want another line to your location. What's it supposed to be? What's the old mantra? Equal or greater, bro. Always get equal or greater. Does that make any sense? If your two and a half inch airline just took out the bulk of the fire, think about FDNY's new engine book. Why do they allow engine three-quarter hose into commercials? Mobility and placement. So what should you always ask for when you ask for another line? Exactly what you want. Hey, I need I need a six-length stretch, inch and three-quarter to the alpha bravo corner. The chief gets on. Hey, it's a commercial. You don't want it? Two and a half? No, I asked what I asked for. We got it knocked. We need a line to do what now? Go through all the racking. Now, hopefully it's never the other way. You've stretched a line with too little knockdown power and you're asking for a bigger line. But guess what? If you do that, ask for the larger line. Could you ask for a heavier piece of equipment?
Dennis Lagueer: Could you be inside with a two and a half and ask for a RAM monitor to your location? inside. Sure. You could do that. What's the nicest thing about a ram honor? Sorry Coralie you're just stock answering. these questions. Yeah. It has a shutoff on it. You could bring one company forward. Right? So again, volume, placement, and velocity, right? I want people Calling for RAM monitors inside. I want people bringing one coupling forward. I want them to know what a RAM monitor can do inside, right? I want someone that has done a good job with the two and a half not to be afraid to call for an inch and three quarter. Corley: Rock and roll, brother. Rock and roll. And that officially. Brings it 248 in the books. Dennis Legar, man, thank you for spending your time with us this evening. If someone wants to get a hold of you, what's the best way to do that? Dennis Lagueer: Dennis look here Dennis at hydranstonnozzles. com. Just look Google it. I feel like I did a lot of lecturing here. I apologize, Corley Corley: you did a lot of lecturing and it was it was it was very valuable to those who who who want to get that value out of it yeah just i just i'm just gonna close it out volume
Dennis Lagueer: placement and velocity, you know, remember that 500 GPM RAM honor is a much higher speed. It's gonna do a lot more damage than two, two and a half. It's okay to bring it inside. It's okay to call for that smaller line. It's okay to have opposing streams. You know, it it it's those Three critical things and master streams have too much volume, too little velocity, and handline stretches. need to be based on what you need at what time, with some general rules around. I still believe in two and a half inch commercials in larger spaces I'm just saying if if you get a good knock, you often don't need another two and a half. You need something smaller and more mobile. And I appreciate I appreciate the bully pulpit Corley, you've done a great thing for the fire service here with the scrap and your management book and stuff. Corley: Hey, thank you for being on here tonight, Dennis. It has been an experience. Coming up this Saturday is Mega Scrap Echo. It is going to be two in, two out. That's what we're going to talk about. The new CFR is being revisited. It's time to make the fire server's voice heard Tune in this Saturday, June 1st for Mega Scrap Echo. Scott Thompson, Nick Ladine, and Sean Duffy. That is a badass lineup. You will not want to miss. These episodes because 2024 is going to continue rolling in style. Thank you, Dennis Legier, for spending your evening with us and sharing your knowledge. The audience. Man, you make the scrap magical. You asked a lot of great questions tonight. I could not keep up. I will not be lying to you. I could not keep up. But the scrap would not exist without you being here Thank you for tuning in live. I love you all. Remember, mutts don't scrap. I hope the tones stay silent unless it is burning. Everybody, stay safe out there.